Perkin Elmer LAMBDA XLS/XLS+
The Lambda XLS is a UV/Vis Spectrophotometer that provides the user with reliability and consistency. The Lambda XLS is specially designed with a split beam operation that ensures high stability and run-to-run reproducibility and it’s ultra long-life Xenon lamp and zero moving parts minimises maintenance and maximises your lab’s uptime.
- External power supply reduces heat in the spectrophotometer – a major source of instrument drift
- An innovate optical design provides full spectra almost instantly
- Full suite of measurement modes: single and multi-wavelength modes, scanning and kinetics
- No moving parts provides for high sensitivity and reliability
- Large, intuitive full graphics display
- Customise up to 90 methods
- Accommodates 10, 20 or 40 mm pathlength cells for maximum application flexibility
|
Perkin Elmer LAMBDA Bio/Bio+
The LAMBDA Bio is designed to provide the user with a high quality UV/Vis Spectrophotometer for all routine life-science calculations. The LAMBDA Bio has a series of pre-programmed methods to support the demands of both molecular and biotech laboratories and with no moving parts, virtually no maintenance and no consumables this makes the LAMBDA Bio the perfect tool when the instrument just needs to work, day-in and day-out.
- DNA, RNA, concentration and purity, and Oligonucleotide methods
- Protein methods including: Direct UV, BCA, Bradford, Lowry, Buiret and Cell density measurements
- Curve fitting with up to 9 standards in triplicate assures accurate results
|
UV/Vis Model 6300
The Model 6300 is designed to provide the user with a high quality, easy to use measurement system for routine analysis. The 6300 has modes for Absorbance, %T and Concentration measurement. Calibration is performed against a blank (Abs and %T) and a standard or factor for Concentration. Wavelength selection is made electronically via a finely geared stepper motor with a displayed resolution of 1nm.
| Wavelength Range (nm) |
320-1000 |
| Resolution (nm) |
1 |
| Accuracy (nm) |
±2 |
| Bandwidth (nm) |
8 |
|
UV/Vis Model 6305
The Model 6305 is designed to provide the user with a high quality, low cost measurement system for routine analysis.
A customised LCD gives simultaneous readout of wavelength and photometric result. Error messages, prompts, mode indication and a choice of concentration units are presented in an easily understood format.
Simple keypad layout and operating protocols ensure reliable operation by unfamiliar users.
| Wavelength Range (nm) |
198-1000 |
| Resolution (nm) |
1 |
| Accuracy (nm) |
±2 |
| Bandwidth (nm) |
8 |
|
UV/VIS Model 6310
An advanced measuring system with modes for Photometrics, Concentration, Quantitation, Kinetics and Scanning. The 6310 will meet the demands of a wide range of applications, especially those in the clinical, veterinary, environmental, general QC and performance testing areas.
| Wavelength Range (nm) |
320-1000nm |
| Resolution (nm) |
1nm |
| Accuracy (nm) |
±2nm |
| Bandwidth (nm) |
8nm |
|
UV/VIS Model 6320D
The Model 6320D is designed to provide the user with a high quality, low cost measurement system for routine analysis. The 6320D has modes for Absorbance, %T and Concentration measurement. Calibration is performed against a blank (Abs or %T) and a standard or factor for Concentration. Wavelength selection is made electronically via a finely geared stepper motor with a displayed resolution of 1nm.
| Wavelength Range (nm) |
320-1000nm |
| Resolution (nm) |
1nm |
| Accuracy (nm) |
±2nm |
| Bandwidth (nm) |
8nm |
|
UV/Vis Model 6400 & 6405
The 6400 series incorporates a wide range of features designed to satisfy the needs of users seeking to maximise the efficiency of routine and specialised UV and visible spectroscopy tasks.
The Model 6400 Visible range unit operates at 320-1100nm. The Model 6405 UV/Visible range unit operates at 190-1100nm.
| Wavelength Range (nm) |
320-1100nm(6400) / 190-1100nm (6405) |
| Resolution (nm) |
0.1nm |
| Accuracy (nm) |
±1.0nm |
| Bandwidth (nm) |
5nm |
|
UV/Vis Model 6500 & 6505
The 6500 series are multi-capability scanning spectrophotometers designed to provide the user with a high quality system which offers all the features required by a scientist to manipulate and process spectral information.
The Model 6500 Visible range unit operates at 320-1100nm.
The Model 6505 UV/Visible range unit operates at 190-1100nm.
| Wavelength Range (nm) |
320-1100nm(6500) / 190-1100nm (6505) |
| Resolution (nm) |
0.1nm |
| Accuracy (nm) |
±1.0nm |
| Bandwidth (nm) |
1.8nm |
|
UV/Vis Model 6700/6705/6715
Model 6700 covers the visible wavelength range with a spectral bandwidth of 4nm.
Model 6705 covers the UV/visible wavelength range with a spectral bandwidth of 4nm.
Model 6715 meets the EP/USP requirements with a spectral bandwidth of 1.5nm across the UV/visible wavelength range.
The large, colour touch-screen display ensures the fastest response to operator input and the clearest presentation of options and results. A sealed QWheelTM is provided for fine cursor control or scrolling. With this cutting-edge user interface and novel operating system the 67 series offer the simplest, most intuitive operation in their class.
| Wavelength Range (nm) |
320-1100nm (6700) 190-1100nm (6705/6715) |
| Resolution (nm) |
0.1nm |
| Accuracy (nm) |
±1.0nm |
| Bandwidth (nm) |
±0.2nm |
|
TE Electrodes
For DNA protein work a specific Tris (TE) is required for long life, stable readings and accuracy. The Jenway Tris (TE) electrode features a narrow shaft for low sample volume and a large ceramic frit to avoid clogging by protein build up.
The Jenway Tris (TE) pH electrode has a specific internal reference solution that does not precipitate and clog the electrode and features a narrow shaft for low sample volume, plus a large ceramic frit to avoid clogging by protein build up.
Price: Call
|